1-866-682-0681 info@thehurleygroup.com

Repair / Manufacturing

Repair / Manufacturing

Repair / Manufacturing

Repair / Manufacturing

Product Repair and Manufacturing Standards

 

  • 18 month warranty on repaired and re-manufactured fans.( Equivalent to OEM new fan warranty)
  • Full load testing at rated voltage and full RPM, at the appropriate tip angle degrees and vibration analysis c/w corresponding report.
  • Quality Control Test Center – full load testing up to 400amps @ 600 volts.
  • HVT has one of only a few fan test chambers in North America built to the International Standard ISO 5801 which can be used for performance validation on repaired and/or re-manufactured ventilation fans.
  • Static and Dynamic (at full rated RPM) balancing c/w vibration analysis report on the vertical, axial and horizontal axis. Fan balancing to the stringent G2.5 balance quality of new fan spec.
  • Fan repairs and re-manufacturing procedures in accordance with our ISO 9002 certification standard.
  • Customizing of fans to meet individual mine requirements.
  • New fan performance on repaired and re-manufactured fans in accordance to AMCA tolerances.
    Fan repairs and re-manufacturing is performed by experienced ventilation mechanics with an extensive understanding of the fits and tolerances that ensure efficient fan performance and longevity.
  • Fan electric motor repairs as per ISO 9001 and EASA standards.
  • Acoustical testing on all re-manufactured and repaired fans.
  • All fan blade angles are set to original manufacturer specifications according to published performance curves at the appropriate operating parameters. These settings are achieved using a protractor to set the pitch angle degrees at the blade tip.
  • All carbon steel items are sandblasted to SSPC-SP6 commercial blast.
  • All sandblasted surfaces are primer painted, two mils DFT and top coated with three mils DFT, paint colour as per customer specifications.
  • All sandblasted components are inspected to verify product structural integrity. Magna flux testing is performed as required.
  • Fan and motor specification information are stamped on a stainless steel plate and riveted to the exterior to the shell casing, next to the conduit box.
  • All mounting hardware is replaced and torque as per new original manufacturer specifications using calibrated equipment ensuring product integrity.
  • Steel cut arrow indicating the direction of the airflow and the rotation is installed adjacent to the conduit box.
  • Written / verbal quotation on repair costs to ventilation and/or Purchasing dept. BEFORE proceeding with repairs, unless otherwise indicated.
  • Repaired and re-manufactured fans are affixed with numbers in order to facilitate tracking to determine fan longevity, warranty, repair frequency and individual unit repair costs.
  • Savings on spare parts and accessories of 10% to 30%.
  • Retrofitting, motor upgrade and fan component change over available on existing fans. (Reduces costs of purchasing new fans. Utilizes present inventory.)
  • HVT will purchase surplus fans and accessories, as required, with credit applied to future fan repairs and/or purchases.
  • Customized specifications can be tailored to suit based on individual mine requirements. Ie lifting lugs/supports, conduit box roll over protection….
  • Free pick-up and delivery ( during normal operating hours of Mon-Fri, 8:00am to 4:00pm.) With pre-arranged commitments.
  • Emergency 24 hour response service (pager #669-3771)
    Standard 10 day turnaround. Rush and Emergency repairs available upon request.
  • Free environmentally controlled warehouse storage of customers critical fans and free cold storage available for none critical and surplus inventory. With pre-arranged service commitments.