Product Repair and Manufacturing Standards
- 18 month warranty on repaired and re-manufactured fans.( Equivalent to OEM new fan warranty)
- Full load testing at rated voltage and full RPM, at the appropriate tip angle degrees and vibration analysis c/w corresponding report.
- Quality Control Test Center – full load testing up to 400amps @ 600 volts.
- HVT has one of only a few fan test chambers in North America built to the International Standard ISO 5801 which can be used for performance validation on repaired and/or re-manufactured ventilation fans.
- Static and Dynamic (at full rated RPM) balancing c/w vibration analysis report on the vertical, axial and horizontal axis. Fan balancing to the stringent G2.5 balance quality of new fan spec.
- Fan repairs and re-manufacturing procedures in accordance with our ISO 9002 certification standard.
- Customizing of fans to meet individual mine requirements.
- New fan performance on repaired and re-manufactured fans in accordance to AMCA tolerances.
Fan repairs and re-manufacturing is performed by experienced ventilation mechanics with an extensive understanding of the fits and tolerances that ensure efficient fan performance and longevity. - Fan electric motor repairs as per ISO 9001 and EASA standards.
- Acoustical testing on all re-manufactured and repaired fans.
- All fan blade angles are set to original manufacturer specifications according to published performance curves at the appropriate operating parameters. These settings are achieved using a protractor to set the pitch angle degrees at the blade tip.
- All carbon steel items are sandblasted to SSPC-SP6 commercial blast.
- All sandblasted surfaces are primer painted, two mils DFT and top coated with three mils DFT, paint colour as per customer specifications.
- All sandblasted components are inspected to verify product structural integrity. Magna flux testing is performed as required.
- Fan and motor specification information are stamped on a stainless steel plate and riveted to the exterior to the shell casing, next to the conduit box.
- All mounting hardware is replaced and torque as per new original manufacturer specifications using calibrated equipment ensuring product integrity.
- Steel cut arrow indicating the direction of the airflow and the rotation is installed adjacent to the conduit box.
- Written / verbal quotation on repair costs to ventilation and/or Purchasing dept. BEFORE proceeding with repairs, unless otherwise indicated.
- Repaired and re-manufactured fans are affixed with numbers in order to facilitate tracking to determine fan longevity, warranty, repair frequency and individual unit repair costs.
- Savings on spare parts and accessories of 10% to 30%.
- Retrofitting, motor upgrade and fan component change over available on existing fans. (Reduces costs of purchasing new fans. Utilizes present inventory.)
- HVT will purchase surplus fans and accessories, as required, with credit applied to future fan repairs and/or purchases.
- Customized specifications can be tailored to suit based on individual mine requirements. Ie lifting lugs/supports, conduit box roll over protection….
- Free pick-up and delivery ( during normal operating hours of Mon-Fri, 8:00am to 4:00pm.) With pre-arranged commitments.
- Emergency 24 hour response service (pager #669-3771)
Standard 10 day turnaround. Rush and Emergency repairs available upon request. - Free environmentally controlled warehouse storage of customers critical fans and free cold storage available for none critical and surplus inventory. With pre-arranged service commitments.